- Brand: NK Optik
- Product Code: NK-OG1716
NK Optik Otoflash G171-6 with N2 GAS PORT - 1 Unit With Nitrogen attachment for CE requirements like hearing aids and dental.
High-Power Stroboscopic-light flash-curing device for 3D Resins and all dental LC materials
POPULAR FOR 3D PRINT RESINS VALIDATED FOR MANY BRANDS
High-Power Stroboscopic-light flash-curing device with N2-gas (nitrogen gas) port for post-curing 3D-printed parts.
Nitrogen Gas helps cure Medical Device print resins removing all Oxygen from the curing chamber. Please Note: Nitrogen Gas not available from Durodent. Check with a local medical gas supplier. eg. Supagas, Pure Gas Australia, BOC Australia
Unit can be used in 3 modes. No Gas, Pre-Flood Gas, Gas.
The Otoflash is a light polymerization chamber for the hardening/curing of light curing resins for jewelry, dental, and otoplastic applications. Two photoflash lamps at the bottom of the curing chamber operate in a work mode with a frequency of 10 flashes per second. The photo-flash lamps produce a very intensive light radiation in a spectrum from 300 up to 700nm. Because of this intensive light radiation, a better hardening of the materials is possible, resulting in materials with good physical values and reduced content of residual monomer versus using other lamp types with a different light emitting spectrum.
The Otoflash G171-6 is compatible with connection to a supply of medical grade Nitrogen. Using Nitrogen prevents oxygen inhibition of polymerisation, surfaces are cured completely non-stick and there is no need to remove or wipe away the inhibition layer.
Stroboscopic Light Technology Simply Effective Track Record of Excellence
▪ A benchmark in the industry
▪ Most highly recommended device in the industry
▪ Most frequently used device in research labs
▪ First device to offer nitrogen curing environment
▪ Decades-long record of superior curing finishes
▪ “Retro” styling, state-of-the-art results!
▪ Stroboscopic light technology provides broad spectrum (250-950nm) and high intensity light
▪ Cures virtually all 3D resins irrespecive of printer used*
▪ Cures virtually all light cure composites for a lastng finish*
▪ Comes with curing trays that allow users to control curing spectrum
▪ Optional nitrogen connectivity for improved surface characterisics and reduced post-processing needs*
Please note: Nitrogen supply and connection equipment is not included with the Otoflash G171-6.
To purchase the optional N2 regulator and connector follow this link: https://www.durodent.com.au/otoflash-n1-connecting-kit
Optional Accessory For Gas Connection
Configuration:
- Size of the polymerisation space: 120 x 120 x 50 mm
- 1x holding tray for the curable items, type 360N2, transmits wavelengths 360-700 nm (= tray with UVB-block)
- 1x holding tray for the curable items, type 280N2, transmits wavelengths 280-700 nm (= tray without UVB-block)
- Protective gas appliance/port: N2
- Rated voltage: 100, 115, 230 Volts AC (adjustable by a selector)
- Rated frequency: 50/60 Hz
- Power input: app. 250 Watts
- Spectral distribution: 300-700 nm, maximum between 400 and 500 nm
- Flash-module: 2 flash-light bulbs, arranged below the device @ 100 Watts*
- Dissipated power: approx. 200 Watts
- Flash frequency: 10 flashes per second
- Digital timer: programmable from 1 to 9,999 flashes
- Unit Measurements: LHW 310 x 310 x 140 mm
- Weight: approx. 7 kg
*Life duration of the flash-bulbs: approx. 250 hours
Package:
1 x G171-6 Unit with GAS PORT
(Optional Extra - N2-connecting kit Australia - N2-cylinder regulator 200 bar with screw thread G 5/8" B-RH-UNI-ISO228 (AS2473), Shaft Length: 80 mm)
- 1x tray insert 280N2 = light transmission 280-950 nm
- 1x tray insert 360N2 = light transmission 360-950 nm (= tray with UV-B block)
- 1x mains power cord: Australia
SPAREPARTS – Available
Flash-module lasts approx. 250-300 working hours.
For curing composites or UV-lacquer, recommend the full range of wavelength (280N2).
280N2 = 280-950nm Trays recommended for e.g. Keystone, Pac-Dent, VOCO, Deltamed, EnvisionTec, Asiga. This tray lasts also a bit longer.
360N2 = 360-950nm Trays recommend for Detax resins, Pro3dure resins, Saremco resin, and for some dentona resins and for some Dreve resins.
The trays should be replaced after approximately 30-50 hours of usage time.
In addition to this, the trays should be replaced if they exhibit strong yellowing, or have been severely scratched or dirtied.
Cracked, dirtied, or yellowed trays reduce the effectiveness of the light irradiation.
NK Optik Otoflash G171-6 with N2 Nitrogen GAS PORT Light Curing Unit - Stroboscopic-Light - 1 Unit
- Brand: NK Optik
- Product Code: NK-OG1716
NK Optik Otoflash G171-6 with N2 GAS PORT - 1 Unit With Nitrogen attachment for CE requirements like hearing aids and dental.
High-Power Stroboscopic-light flash-curing device for 3D Resins and all dental LC materials
POPULAR FOR 3D PRINT RESINS VALIDATED FOR MANY BRANDS
High-Power Stroboscopic-light flash-curing device with N2-gas (nitrogen gas) port for post-curing 3D-printed parts.
Nitrogen Gas helps cure Medical Device print resins removing all Oxygen from the curing chamber. Please Note: Nitrogen Gas not available from Durodent. Check with a local medical gas supplier. eg. Supagas, Pure Gas Australia, BOC Australia
Unit can be used in 3 modes. No Gas, Pre-Flood Gas, Gas.
The Otoflash is a light polymerization chamber for the hardening/curing of light curing resins for jewelry, dental, and otoplastic applications. Two photoflash lamps at the bottom of the curing chamber operate in a work mode with a frequency of 10 flashes per second. The photo-flash lamps produce a very intensive light radiation in a spectrum from 300 up to 700nm. Because of this intensive light radiation, a better hardening of the materials is possible, resulting in materials with good physical values and reduced content of residual monomer versus using other lamp types with a different light emitting spectrum.
The Otoflash G171-6 is compatible with connection to a supply of medical grade Nitrogen. Using Nitrogen prevents oxygen inhibition of polymerisation, surfaces are cured completely non-stick and there is no need to remove or wipe away the inhibition layer.
Stroboscopic Light Technology Simply Effective Track Record of Excellence
▪ A benchmark in the industry
▪ Most highly recommended device in the industry
▪ Most frequently used device in research labs
▪ First device to offer nitrogen curing environment
▪ Decades-long record of superior curing finishes
▪ “Retro” styling, state-of-the-art results!
▪ Stroboscopic light technology provides broad spectrum (250-950nm) and high intensity light
▪ Cures virtually all 3D resins irrespecive of printer used*
▪ Cures virtually all light cure composites for a lastng finish*
▪ Comes with curing trays that allow users to control curing spectrum
▪ Optional nitrogen connectivity for improved surface characterisics and reduced post-processing needs*
Please note: Nitrogen supply and connection equipment is not included with the Otoflash G171-6.
To purchase the optional N2 regulator and connector follow this link: https://www.durodent.com.au/otoflash-n1-connecting-kit
Optional Accessory For Gas Connection
Configuration:
- Size of the polymerisation space: 120 x 120 x 50 mm
- 1x holding tray for the curable items, type 360N2, transmits wavelengths 360-700 nm (= tray with UVB-block)
- 1x holding tray for the curable items, type 280N2, transmits wavelengths 280-700 nm (= tray without UVB-block)
- Protective gas appliance/port: N2
- Rated voltage: 100, 115, 230 Volts AC (adjustable by a selector)
- Rated frequency: 50/60 Hz
- Power input: app. 250 Watts
- Spectral distribution: 300-700 nm, maximum between 400 and 500 nm
- Flash-module: 2 flash-light bulbs, arranged below the device @ 100 Watts*
- Dissipated power: approx. 200 Watts
- Flash frequency: 10 flashes per second
- Digital timer: programmable from 1 to 9,999 flashes
- Unit Measurements: LHW 310 x 310 x 140 mm
- Weight: approx. 7 kg
*Life duration of the flash-bulbs: approx. 250 hours
Package:
1 x G171-6 Unit with GAS PORT
(Optional Extra - N2-connecting kit Australia - N2-cylinder regulator 200 bar with screw thread G 5/8" B-RH-UNI-ISO228 (AS2473), Shaft Length: 80 mm)
- 1x tray insert 280N2 = light transmission 280-950 nm
- 1x tray insert 360N2 = light transmission 360-950 nm (= tray with UV-B block)
- 1x mains power cord: Australia
SPAREPARTS – Available
Flash-module lasts approx. 250-300 working hours.
For curing composites or UV-lacquer, recommend the full range of wavelength (280N2).
280N2 = 280-950nm Trays recommended for e.g. Keystone, Pac-Dent, VOCO, Deltamed, EnvisionTec, Asiga. This tray lasts also a bit longer.
360N2 = 360-950nm Trays recommend for Detax resins, Pro3dure resins, Saremco resin, and for some dentona resins and for some Dreve resins.
The trays should be replaced after approximately 30-50 hours of usage time.
In addition to this, the trays should be replaced if they exhibit strong yellowing, or have been severely scratched or dirtied.
Cracked, dirtied, or yellowed trays reduce the effectiveness of the light irradiation.